Skip to content
HAMELBUILDING TECHNOLOGIESHamel Building Technologies

The Aero building automation platform

Building automation you actually own.

Aero brings BACnet and Metasys N2 buildings under modern supervisory control, with edge controllers, an on-premises supervisor and secure remote access. No point licensing. No annual SMA.

  • BACnet/IP
  • BACnet MS/TP
  • Metasys N2
  • HTML5 AeroView
  • Outbound-only mTLS
LAN1 · 1GLAN2 · 2.5GHDMISVCPWRRUNNETCOMAeroNode 485COM1 RS-485ABGCOM2 RS-485ABGCOM3 RS-485ABGCOM4 RS-485ABGDI12CDO12C7–36V+−AeroNodeAN-485
0point licenses

No point or device licensing

AeroNode and AeroServer carry no capacity tiers and no license files. Add devices and points as the job needs them.

$0annual SMA

No annual SMA

Firmware and software updates are included. You never pay a maintenance agreement to stay current or secure.

0inbound ports

Outbound-only connectivity

Nodes dial out over authenticated, encrypted connections. Supervision and remote access work without opening the building firewall.

HTML5no Java, no plug-ins

HTML5 everywhere

AeroView runs in any modern browser. No Java, no thick client, and no workstation licenses to engineer or operate a node.

The product line

One platform, from the mechanical room to the portfolio.

Every Aero product shares one data model and one wire protocol, so a thermostat, a controller and a campus supervisor behave like parts of the same system, because they are.

View all products
LAN1 · 1GLAN2 · 2.5GHDMISVCPWRRUNNETCOMAeroNode 485COM1 RS-485ABGCOM2 RS-485ABGCOM3 RS-485ABGCOM4 RS-485ABGDI12CDO12C7–36V+−AeroNodeAN-485

Supervisory controllers

AeroNode

Fanless DIN-rail controllers with four serial trunks, dual Ethernet and onboard I/O. They run logic, schedules, trends and alarms locally.

  • AeroNode 485
  • AeroNode 232
  • Wi-Fi · LTE · NVMe options
Explore
AeroServerStation · Riverside Medical CampusSTATIONRiverside MedicalMain HospitalAN-01 · Mech Room 2AN-02 · PenthouseAN-03 · Central PlantMedical Office BldgAN-04 · Level 1AN-05 · RoofParking StructureAN-06 · ExhaustMain Hospital · Level 2 · VAV zones71.8°72.4°74.9°70.9°72.1°73.0°Nodes online6 / 6Points4,812Active alarms3Alarm consoleALL NODESHIGHCH-2 condenser water temp highAN-0314:29MEDVAV-2-14 airflow below minimumAN-0114:12LOWAHU-4 filter differential pressureAN-0513:47ACKEF-3 status mismatch (acknowledged)AN-0612:05

On-premises supervisor

AeroServer

Aggregate every node on a site into one station, with a site-wide alarm console, graphics and role-based access. Unlimited nodes.

  • Windows desktop or service
  • Unlimited nodes & points
  • No annual SMA
Explore
AeroViewRiverside Medical · Mechanical Room 22 ALM14:32DashboardEquipmentTrendsAlarmsSchedulesProgramsSettingsAHU-1 · Supply AirOCCUPIEDOAT88.2°FMAT74.1°FSAT55.0°FDSP1.25 inFAN72 %CHW48 %Zone temp72.4 °FSetpoint72.0 °FEcon OA20 %Supply air temperature · 24 hSAT / SP

Controller + 10.1″ display

AeroNode Touch

A complete AeroNode behind an optically bonded 10.1-inch touchscreen.

Explore
Zone 3BCOOL72°Set 71°RH44%CO₂612OCCYesAeroStatZone 3BCOOL70°Set 71°RH44%CO₂612OCCYes−+AeroStat

BACnet thermostats

AeroStat

Configurable MS/TP thermostats with up to 15 I/O and optional occupancy, CO₂ and Wi-Fi.

Explore
AeroUCIN DEVELOPMENT

Unitary controllers

Coming soon

AeroUC

Programmable BACnet controllers for VAV boxes, fan coils, heat pumps and rooftop units.

Explore

Licensing

Stop paying to keep what you already bought.

Most supervisory platforms charge for capacity up front, then charge again every year to stay current. Aero doesn't. The controller you install is the controller you own.

  • No point or device licensing on AeroNode or AeroServer
  • No annual SMA to receive updates
  • No license keys tied to hardware
Capacity
Typical: Priced in device or point tiers. Growth means buying a license upgrade.
Aero: No capacity tiers. Add devices and points as the job grows.
Maintenance
Typical: An annual software maintenance agreement is required to stay on current releases.
Aero: Firmware and software updates are included. No SMA.
License files
Typical: Licenses are bound to hardware; moving to new hardware can mean transfer fees.
Aero: No license files to lose, transfer or renew.
Engineering
Typical: Desktop engineering tools, often licensed per seat.
Aero: Engineer and operate every node from a browser.
Remote access
Typical: VPN appliances, jump boxes or port forwarding.
Aero: AeroConnect: outbound-only remote access, no VPN (optional service).

Describes common industry licensing practices; specific terms vary by manufacturer and agreement. AeroConnect cloud remote access is an optional subscription service.

Architecture

Edge-first. Outbound-only. Open protocols.

AeroNodes do the work at the edge and keep running on their own. Supervisors and the cloud add visibility, but they never reach into the building.

The edge is autonomous
Logic, schedules, trends and alarms run on the node. If the network drops, the building keeps running.
Nodes always dial out
Each node keeps one outbound, encrypted connection to AeroServer or AeroConnect, and all supervision travels over it. Nothing connects in to the building.
Standards at the field level
BACnet/IP, BACnet MS/TP and Metasys N2 on the field side, plus a BACnet server so existing front ends can see Aero points.
  1. 1

    Operators

    Any browser, on site or remote. AeroView is pure HTML5, with no Java and no thick client.

  2. 2

    AeroServer · AeroConnect

    On-premises supervisor and optional cloud relay for remote access.

  3. 3

    Outbound mTLS

    Every node dials out over one mutual-TLS stream. No inbound firewall rules.

  4. 4

    AeroNode

    Supervisory controllers that run logic, schedules, trends and alarms locally.

  5. 5

    Field buses

    BACnet MS/TP, BACnet/IP and Metasys N2 devices, including AeroStat thermostats.

Capabilities

Everything a supervisory controller should do, done in the browser.

AeroView is the same HTML5 interface on every node and on AeroServer. Commission, program, operate and troubleshoot any node from a browser, with nothing to install.

Explore the platform

Driver framework

Each field protocol runs as its own supervised driver process, so a misbehaving device or a hung serial port can't take down the controller. Every serial port is driver-agnostic, and new protocols arrive as signed firmware updates.

Program sheets

Drag-and-wire control logic with live values: about 40 blocks including PID, formula, delay, edge detection and alarm blocks. Package proven sequences as versioned macros and reuse them across jobs.

Schedules

Weekly schedules with date-range exceptions and a month view. Device schedules stay in sync with BACnet Schedule objects, and node schedules command points at the priority you choose.

Trending on the edge

Interval or change-of-value logging with per-point retention, stored on the node itself. Multi-point charts and CSV export in any browser.

Alarm management

Point limit and state alarms with delays and deadbands, device-offline alarms and logic-driven alarms, with a full acknowledge/clear lifecycle that writes acknowledgements back to BACnet devices.

Dashboards & equipment graphics

Build dashboards from gauges, trends, alarm lists, setpoint adjusters and floor plans. Generate equipment graphics from 11 templates (AHU, VAV, RTU, FCU, boiler, chiller and more).

BACnet server

Publish Aero points as BACnet/IP objects so an existing front end, whether Niagara, Metasys or another BACnet workstation, can read and command them during a phased migration.

Signed firmware, automatic rollback

Every firmware release is cryptographically signed and verified before it installs. If a new version fails to start, the node automatically restores the previous one.

Integration

Speaks the building's language, old and new.

Supervise modern BACnet systems and legacy Metasys N2 trunks from the same controller, and hand points to any BACnet front end during a phased migration.

BACnet/IP

Shipping

Full client: discovery, polling and COV, priority writes, foreign-device registration, device alarms and schedules.

BACnet MS/TP

Shipping

Native RS-485 trunks on every AeroNode, with a frame log for troubleshooting.

Metasys N2

Shipping

N2 Open supervision: address scan discovery, point reads, and output overrides with release.

BACnet server

Shipping

Selected points published as BACnet/IP objects, plus global schedules as BACnet Schedule objects.

Every AeroNode serial port is driver-agnostic. Our goal is to support the open RS-485 and RS-232 protocols found in buildings through Aero drivers, delivered to installed controllers as signed firmware updates.

On the driver roadmap

  • Modbus RTU (RS-485) and Modbus TCP
  • RS-232 serial device drivers
  • Additional open RS-485 protocols
  • BACnet Secure Connect (BACnet/SC) transport

Dealer network

Sold, installed and supported locally.

Aero is available only through authorized dealers: controls contractors who design, install and stand behind every system, backed by factory support from HBT.

Authorized dealerEXCLUSIVE IN LA · NATIONWIDE

Vertex Control Systems

Vertex Control Systems LLC

Covington, LouisianaThe only authorized Aero dealer in Louisiana, serving customers nationwide

Put Aero on your next project.

Authorized dealers design, install and support every Aero system. Find the dealer for your territory, or talk to us about becoming one.